Mfg Part Number: 646-3138-001 | Alternate P/N: 6463138001 | NSN : 5950-01-331-5911 |
NIIN : 013315911 | CAGE Code : 24226 | Manufacturer: Gowanda Holdings Llc |
Item Name : Transformer Radio F | FSC : 5950 Coils and Transformers |
Thank you for choosing NSN Catalogue for all your operational needs. You have reached our NSN RFQ Page which features our in-demand NSN 5950-01-331-5911 part 646-3138-001 with Transformer Radio F manufactured by MFG Gowanda Holdings Llc. Some of these items include part number 646-3138-001, and various others, all of which have been subjected to a number of quality assurance measures, tests, verifications, and assessments. At NSN Catalogue, we make it our priority to only source from top global manufacturers that we trust, assuaging the worry of receiving quality items from us.
The NSN 5950-01-331-5911 products 646-3138-001 that we feature by MFG Gowanda Holdings Llc are paired alongside CAGE Code 24226. NSN Catalogue utilizes CAGE Codes, allowing our customers to narrow down our vast listings by using our optimized search engine and filters. If you are familiar with the CAGE Codes associated with the particular NSN parts and components you wish to purchase, we invite you to use them. If you have more information regarding the NSN items you wish to purchase, please provide such details in the provided RFQ form below. When you fill out a form, in return, you will be provided a competitive quote for your comparisons in just 15 minutes or less.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-331-5911 Item Description: Transformer Radio F | 5950 | 013315911 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
646-3138-001 | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABFE | HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION | VIBRATION RESISTANT |
ABHP | OVERALL LENGTH | 0.520 INCHES MAXIMUM |
ABHY | TURN QUANTITY | 5-1/2 SINGLE COMPONENT SINGLE PRIMARY |
ABHY | TURN QUANTITY | 5-1/2 SINGLE COMPONENT SINGLE SECONDARY |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 0.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 0.400 INCHES NOMINAL SINGLE MOUNTING FACILITY SINGLE CENTER GROUP |
ABMK | OVERALL WIDTH | 0.520 INCHES MAXIMUM |
ACYV | INDUCTANCE RATING | 163.00 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE SECONDARY AND 300.00 MICROHENRIES MAXIMUM SINGLE COMPONENT SINGLE SECONDARY |
ACZB | FREQUENCY RATING | 10.0 KILOHERTZ MINIMUM SINGLE COMPONENT AND 1.0 MEGAHERTZ MAXIMUM SINGLE COMPONENT |
ACZP | COIL FORM TYPE | SOLID SINGLE COMPONENT |
ADAU | BODY HEIGHT | 0.375 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 125.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AXGY | MOUNTING METHOD | TERMINAL SINGLE GROUP |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 1 SECONDARY SINGLE COMPONENT |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE SECONDARY |
TEST | TEST DATA DOCUMENT | 13499-646-3138 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA |
TTQY | TERMINAL TYPE AND QUANTITY | 4 PIN |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE PRIMARY AND WINDING TURNS SINGLE COMPONENT SINGLE PRIMARY |
ACYV | INDUCTANCE RATING | 163.00 MICROHENRIES MINIMUM SINGLE COMPONENT SINGLE PRIMARY AND 300.00 MICROHENRIES MAXIMUM SINGLE COMPONENT SINGLE PRIMARY |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT SINGLE SECONDARY AND WINDING TURNS SINGLE COMPONENT SINGLE SECONDARY |
CQPZ | WINDING CONDUCTOR SIZE | 0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT SINGLE PRIMARY |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.
Request for Quote